High Inlet Temperature Air-cooling Refrigerated Air Dryer
Inlet temperature: ≤ 80C
Cooling method: Air cooling
Inlet pressure: 0.4~1.3Mpa
Pressure drop: ≤ 0.03Mpa
Refrigerant: R22/R134A/R407c
- Description
- Specifications
The front air-cooling pre-cooler and the condenser in the cooling system use the forced ventilation system for cooling, the advantages for air cooling system: Easy to install and maintain, little early investment, low operation cost, suitable for the conditions with comfortable environment temperature and good ventilation, especially suitable for the areas free of water or short of water resources. The machine use a high quality fan motor, mostly applied to the low load and movable situations, which are largely influenced by the environment temperature.
Model | Capacity | Voltage | Cooling Power | Fan Power | Pipe connection diameter | Dimension | Weight | ||
Nm3/min | V/Hz | HP/Kw | W | L | W | H | Kg | ||
ELH-10HA | 1.2 | 220/50 | 1/0.85 | 90 | ZG1 | 630 | 450 | 640 | 50 |
ELH-15HA | 2.4 | 220/50 | 1/0.85 | 90 | ZG1 | 700 | 450 | 830 | 80 |
ELH-30HA | 3.8 | 220/50 | 1.25/1.25 | 140 | ZG1 1/2 | 850 | 500 | 920 | 105 |
ELH-50HA | 6.5 | 220/50 | 1.5/1.5 | 180 | ZG1 1/2 | 880 | 550 | 1020 | 150 |
ELH-60HA | 8.5 | 220/50 | 2.5/1.8 | 180 | ZG1 1/2 | 880 | 550 | 1020 | 160 |
ELH-75HA | 10.7 | 380/50 | 3/2.5 | 2*140 | ZG2 | 1180 | 670 | 1080 | 240 |
ELH-100HA | 13.5 | 380/50 | 3/2.5 | 2*140 | ZG2 | 1180 | 670 | 1080 | 260 |
ELH-120HA | 18 | 380/50 | 3.6/3 | 2*140 | DN65 | 1360 | 710 | 1220 | 310 |
ELH-150HA | 23 | 380/50 | 5/4 | 2*140 | DN80 | 1360 | 710 | 1220 | 400 |
ELH-200HA | 28 | 380/50 | 6/4.5 | 2*140 | DN80 | 1650 | 750 | 1290 | 450 |
ELH-250HA | 33 | 380/50 | 7.5/6.5 | 6(3)*180 | DN100 | 1840 | 850 | 1620 | 780 |
ELH-400HA | 45 | 380/50 | 10.5/8.8 | 6(3)*180 | DN125 | 2000 | 950 | 1740 | 820 |
ELH-500HA | 55 | 380/50 | 12/10.2 | 6(3)*180 | DN125 | 2200 | 1050 | 1910 | 900 |
ELH-600HA | 65 | 380/50 | 15/13 | 6(3)*180 | DN125 | 2550 | 1100 | 1940 | 1100 |